在醫院各科室中,醫療用內窺鏡的使用嚴格,內窺鏡對使用環境的要求:室內環境以暗室環境為主,避免強光直射,手術開始關閉日光燈,用無影燈照明,術前室內的溫度保持在22℃~25℃、濕度50%左右、防酸、防堿、防蒸氣。避免強電、電磁場的干擾。手術中確保電壓穩定,連續穩壓器維持電壓220V以免損壞精密儀器。
In all departments of the hospital, the use of medical endoscopes is strict, and the requirements for the use environment of endoscopes are: the indoor environment is dominated by dark room environment, avoiding direct glare. The operation starts with the fluorescent lamp turned off, and shadowless lamps are used for lighting. Before the operation, the indoor temperature is kept at 22 ℃~25 ℃, the humidity is about 50%, and the room is acid proof, alkali proof, and vapor proof. Avoid interference from strong electricity and electromagnetic fields. Ensure voltage stability during surgery, and maintain a continuous voltage regulator of 220V to prevent damage to precision instruments.
室內儀器定位放置:手術間的電源插座應為屋頂懸掛式,避免因工作人員走動碰脫電源插座而使電源線受干擾,保證手術的順利進行,同時也避免由于電壓不穩而造成儀器損壞。
Indoor instrument positioning and placement: The power socket in the operating room should be a rooftop suspended type to avoid interference with the power cord caused by personnel moving and touching the power socket, ensuring the smooth progress of the surgery, and also avoiding instrument damage due to unstable voltage.
監視器:一般監視器在安裝時已經都是有相關技術人員進過測試并調整到了佳顯示狀態,所以不建議使用者自行調試。如果監視器不顯示,請檢查插線板和電源線的連接,顯示器開關是否處于打開狀態、攝像系統是否處于打開狀態、攝像系統的輸出是否正確的連接到監視器的輸入端口。
Monitor: Generally, monitors have been tested and adjusted to a good display state by relevant technical personnel during installation, so it is not recommended for users to debug on their own. If the monitor does not display, please check the connection between the patch panel and power cord, whether the monitor switch is on, whether the camera system is on, and whether the output of the camera system is correctly connected to the input port of the monitor.
顏色失真后可將攝像系統的光學接口對準顏色比較鮮明的物體或圖片,通過監視器上的菜單進行對比度、飽和度、亮度的調節。避免強磁物體靠近監視器,定期作消磁保養,當磁化嚴重或消磁失效的時候,請聯系廠家技術人員。
After color distortion, the optical interface of the camera system can be aimed at objects or images with bright colors, and contrast, saturation, and brightness can be adjusted through the menu on the monitor. Avoid strong magnetic objects approaching the monitor and regularly perform demagnetization maintenance. In case of severe magnetization or demagnetization failure, please contact the manufacturer's technical personnel.
攝像系統和光源:雖說很多醫療內窺鏡聲明光學接口是防水的,但光學接口和連接線不建議,可用套套上,每次使用時套,這樣可以大大增加光學接口的使用壽命,如必須請用低溫熏蒸的方法。
Camera system and light source: Although many medical endoscopes declare that the optical interface is waterproof, it is not recommended to disinfect the optical interface and connecting wires. You can use an antibacterial cover and disinfect the cover every time you use it. This can greatly increase the service life of the optical interface. If disinfection is necessary, please use low-temperature fumigation.
內窺鏡設備維修人員提醒您,插口不能強插拔,要對準十二點的位置進行直插、直拔輕拿輕放,定期作白平衡校準。防止光學接口接觸液體,即使聲稱是防水的設備,所以不要將調焦頭及連線浸泡,如不甚接觸葡萄糖一類的液體請手術后立即用干布擦干凈光學接口表面液體。
The maintenance personnel of the endoscope equipment remind you that the socket cannot be forcefully inserted or unplugged. It should be aligned with the position of twelve o'clock for direct insertion, easy handling, and regular white balance calibration. Prevent the optical interface from coming into contact with liquids, even if claimed to be waterproof equipment, so do not soak and disinfect the focusing head and wiring. If there is little contact with liquids such as glucose, please immediately wipe the surface liquid of the optical interface with a dry cloth after surgery.
防止卡口結晶運動不靈活,如果出現異常請不要勉強使用。光纜不可用浸泡方式或高溫高壓方法,如需請用低溫熏蒸或淡酒精擦拭表面的方法進行。使用者要細心記錄光源燈泡的使用時間,臨近使用壽命時準備備用燈泡。光源燈泡有使用壽命的限制,建議不使用時立即關閉光源。更多事項就來我們網站
http://www.365shop.cc咨詢吧!
To prevent inflexible movement of crystal in the bayonet, please do not force it to be used in case of abnormalities. Optical cables cannot be disinfected by soaking or high-temperature high-pressure methods. If disinfection is required, please use low-temperature fumigation or light alcohol to wipe the surface for disinfection. Users should carefully record the usage time of the light source bulb and prepare a spare bulb as it approaches its lifespan. The light source bulb has a limited lifespan, and it is recommended to immediately turn off the light source when not in use. For more information, come to our website http://www.365shop.cc Consult!