內窺鏡設備維修檢查的基本方法是先外后內,先簡單后復雜,先供電后電路,再檢查電路中的插頭和詳細單元。還可根據數控系統的報警信息提示查看設備報警提示的相關部位,并可通過系統參數和檢測功能查看設備的運行狀態、負載、電流等狀態,逐步減少故障范圍,很后確定故障點。維修更換后,故障排除。
The basic method of maintenance and inspection of endoscope equipment is from outside to inside, from simple to complex, from power supply to circuit, and then check the plug and detailed unit in the circuit. It can also check the relevant parts of the equipment alarm prompt according to the alarm information prompt of the NC system, and check the operation state, load, current and other states of the equipment through the system parameters and detection function, so as to gradually reduce the fault range and determine the fault point later. Troubleshooting after maintenance and replacement.
我們在維修內窺鏡時,一定要注意穿插感染的問題。例如:由于操作不規范,體液檢測設備濺出的體液污染儀器表面,試劑污染儀器表面,激光設備過程中殘留的表皮細胞、放化療設備放射性粉塵的污染、環境污染、維修工具的污染等。
When we repair the endoscope, we must pay attention to the problem of interspersed infection. For example, due to non-standard operation, the body fluid splashed by the body fluid detection equipment pollutes the surface of the instrument, the reagent pollutes the surface of the instrument, the residual epidermal cells in the treatment process of the laser treatment equipment, the radioactive dust pollution of the radiotherapy and chemotherapy equipment, the environmental pollution, the pollution of the maintenance tools, etc.
維修此類設備時要注意,很好佩戴一次性手套,避免尿液、血液、激光后殘留的表皮細胞、放射性粉塵等濺到皮膚上觸碰。修復工作完成后,用肥皂和水徹底清洗裸露的皮膚,同時停止對所用工具的清潔和。
When repairing such equipment, pay attention to wearing disposable gloves to avoid splashing and touching the skin with urine, blood, residual epidermal cells after laser treatment and radioactive dust. After the repair work is completed, wash the exposed skin thoroughly with soap and water, and stop the cleaning and disinfection of the tools used.
此外內窺鏡維修檢測設備的包裝強度檢測包括包裝材料的抗拉強度、復合膜的剝離強度、熱封強度、撕裂強度、抗穿刺強度等指標??估瓘姸仁侵覆牧显跀嗔亚俺惺艿暮艽髴χ?。經測試,可有效處理因所選包裝材料機械強度不足而因外力造成的包裝破損、破損。
In addition, the packaging strength test of endoscope maintenance and testing equipment includes the tensile strength of packaging materials, peel strength of composite film, heat sealing strength, tear strength, puncture resistance and other indicators. Tensile strength refers to the large stress value borne by a material before fracture. After testing, it can effectively deal with the packaging damage and damage caused by external force due to the insufficient mechanical strength of the selected packaging materials.
內窺鏡維修是檢測復合膜中各層之間的結合強度。如果粘合強度過低,在封裝應用中很容易出現層與層分離導致的滲漏等問題。熱封強度是檢測封口的強度。產品在儲運過程中,一旦熱封強度過低,就會造成熱封開裂、內容物滲漏等問題。
Endoscope maintenance is to detect the bonding strength between layers in the composite membrane. If the bonding strength is too low, leakage caused by layer separation is easy to occur in packaging applications. Heat sealing strength is to test the strength of sealing. In the process of storage and transportation, once the heat seal strength is too low, it will cause heat seal cracking, content leakage and other problems.
Therefore, the daily management of endoscope to ensure its safety and effectiveness must be strictly controlled. For more information, please visit www.jiangrenyiliao.com Cn for consultation.